Plane length L = 50 m
Plane slope So = 0.007
Manning's n = 0.06
rainfall excess i = 45 mm/hr
Kinematic flow number K = (SoL)/(Fo2ho)
Calculate equilibrium outflow; establish rating; calculate ho from rating; calculate mean velocity vo,
and Froude number.
Equilibrium outflow qe = iL = (45 mm/hr × 50 m × 0.001 m/mm) / (3600 s/hr) = 0.000625 m3/s/m
Rating: qe = b hom
b = (1/n) So1/2 = (1/0.06) (0.007)1/2 = 1.394
Choose m = 5/3 [Manning friction in wide channels (overland flow)]; 1/m = 3/5 = 0.6
Calculate he = (qe/b) 1/m = (0.000625/1.394)0.6 = 0.00979 m
ho = he = 0.00979 m
Calculate vo = qe / he = (0.000625/0.00979) = 0.0638 m/s
Calculate Fo2 = vo2 / (gho) = (0.0638)2 / (9.81 × 0.00979) = 0.042
Calculate K = (SoL)/(Fo2ho) = (0.007 × 50) / (0. 042 × 0.00979) = 851 > 20.
The flow is kinematic. ANSWER
|