CIVE 445 - ENGINEERING HYDROLOGY

SPRING 2005 - MIDTERM 2 - SOLUTION

PROBLEM 2

To convolute the 2-hr unit hydrograph with the effective storm pattern defined at intervals of 3 hr, it is necessary to change the unit hydrograph duration to 3 hr. We use the S-hydrograph method to change the 2-hr UH to 3-hr UH.

To calculate the flood hydrograph, for 6 cm, it is 6 times; for 9 cm, it is 9 times (lagged 3 hr).

Time2-hr UH2-hr SH Lagged 3 hr3-hr UH6×UH9×UH
(lagged 3 hr)
Flood
hydrograph
(hr)(mm/hr)mm/h (ha)(m3/s)(m3/s)(m3/s)(m3/s)
000 00.00000
155 03.3320020
21515 010.0060060
33035 023.331400140
46075 546.6728030310
570105 1560.0036090450
660135 3566.67400210610
755160 7556.67340420760
845180 10550.00300540840
935195 13540.00240600840
1025205 16030.00180510690
1115210 18020.00120450570
125210 19510.0060360420
130210 2053.3320270290
140210 2100.000180180
150210 2100.0009090
160210 2100.0003030
170210 2100.00000
420- -420.002520
[= 420×6]
3780
[= 420×9]
6300
[= 420×15]

Problem 3

 