Tecate Creek Restoration Flood Hydrograph Summary

Reach No., flood frecuency, without/with channel transmission losses

Peak discharge


16, 100-yr, without
Qp = 779 m3/s

17, 100-yr, without
Qp = 767 m3/s

16, 100-yr, with
Qp = 770 m3/s

17, 100-yr, with
Qp = 753 m3/s
Adopted
design
discharge:

Qp = 770 m3/s


16, 50-yr, without
Qp = 680 m3/s

17, 50-yr, without
Qp = 689 m3/s

16, 50-yr, with
Qp = 672 m3/s

17, 50-yr, with
Qp = 675 m3/s
Adopted
design
discharge:

Qp = 675 m3/s


16, 25-yr, without
Qp = 329 m3/s

17, 25-yr, without
Qp = 373 m3/s

16, 25-yr, with
Qp = 322 m3/s

17, 25-yr, with
Qp = 396 m3/s
Adopted
design
discharge:

Qp = 396 m3/s


16, 10-yr, without
Qp = 214 m3/s

17, 10-yr, without
Qp = 283 m3/s

16, 10-yr, with
Qp = 206 m3/s

17, 10-yr, with
Qp = 268 m3/s
Adopted
design
discharge:

Qp = 268 m3/s


16, 5-yr, without
Qp = 149 m3/s

17, 5-yr, without
Qp = 206 m3/s

16, 5-yr, with
Qp = 141 m3/s

17, 5-yr, with
Qp = 190 m3/s
Adopted
design
discharge:

Qp = 190 m3/s


16, 2-yr, without
Qp = 66 m3/s

17, 2-yr, without
Qp = 102 m3/s

16, 2-yr, with
Qp = 58 m3/s

17, 2-yr, with
Qp = 87 m3/s
Adopted
design
discharge:

Qp = 87 m3/s

04 February 2005