online_scour_hec18:  Calculation of bridge scour using the HEC-18 formula   


Formula:

Fr1 = v1/(g y1)1/2

ys /y1 = 2 K1 K2 K3 (a / y1)0.65 Fr10.43

[ SI Units (metric):  ys, y1, a, and L in m ]
[ U.S. Customary Units:  ys, y1, a, and L in ft ]
[ Fr = Froude number; g = gravitational acceleration ]


Reference:

Evaluating Scour at Bridges,
FHWA Hydraulic Engineering Circular No. 18,
Fifth Edition, 2012.



INPUT DATA:      [Description]     [Sample Input]

Select:      

Flow depth y1 :      

 

Flow velocity v1 :      

 

Pier width a :      

 

Pier length L :      

 

Angle of attack θ of the flow (degrees):      

 

Pier nose shape:      

Bed condition:      

OUTPUT:

System of units:  SI units (metric)

Pier nose shape:  Square nose

Bed condition:  Clear-water scour


  Scour depth ys :     


Press button to
or recalculate

  Your request was processed at  04:06:03 am on December 23rd, 2024   [ 241223  04:06:03 ].


Thank you for running   online_scour_hec18   Please call again.   [171021]

Documents in Portable Document Format (PDF) require Adobe Acrobat Reader 5.0 or higher to view; download Adobe Acrobat Reader.